Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1005120

RESUMO

【Objective】 To determine the ELISA kit for screening convalescence plasma with high potency of SARS-CoV-2 IgG by comparing and analyzing the plasma detection results of convalescent plasma collected in different periods via ELISA kits from two manufacturers and the results of mixed plasma with different potency via pseudovirus neutralization experiments. 【Methods】 Two ELISA kits from different manufacturers(named A, B) were used to detect the plasma of 269 convalescent patients collected from Feb.2020~Jan.2022. The correlation and concordance rate of the two results were analyzed to determine the kit preliminarily. According to the titers of diluted series of standard of the preliminary selected kit, 5 mixed plasma samples (G4-G128) with different potency were prepared. The correlation of ELISA IgG results of product A/B, as well as the pseudovirus neutralization test of the original strain, Omicron mutant BA.1 and BA.2 strains were analyzed. Combined with the outside-well dilution mode of the strongly positive samples, the kit for high potency of SARS-CoV-2 IgG screening was determined. 【Results】 When the internal control reference B2 was used as the standard, the detection sensitivity of product A and B was 1∶32 vs 1∶8; the detection sensitivity of product A was 4 times that of product B. The correlation Pearson r between the results given by two kits was 0.944 1(P<0.000 1). Product B with low sensitivity was primarily selected as an alternative kit. The ELISA IgG results of samples from mixed plasma showed that the order of correlation r between product A and B was 0.988. The correlation r between product A and neutralization antibody potency of the three viruses was original strain (0.978)>BA.2(0.970)>BA.1(0.799); the order of correlation r between ELISA IgG results of product B and neutralization antibody potency of the three viruses was original strain(0.994)>BA.2(0.968)>BA.1(0.804). If twice-diluted B2 was taken as the excellent standard, 55.4% of product B met the criterion, while 47.2% of product A met.For positive plasma with high IgG potency, the product B kit required a lower dilution of the sample, which was more convenient to operate. 【Conclusion】 Both of the ELISA IgG kit from product A and B can be used to screen IgG antibodies of SARS-CoV-2, while product B is more suitable for screening positive plasma with high IgG potency.

2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1004787

RESUMO

【Objective】 To determine the best collection time period of plasma which can be used for human COVID-19 immunoglobulin for intravenous injection through SARS-CoV-2-IgG change and neutralizing antibody distribution against different virus strain in representative mixed plasma before and after Omicron strain infection by ELISA and pseudovirus neutralization test. 【Methods】 An ELISA method for quantitative detection of SARS-CoV-2-IgG was established and its linear range,accuracy and precision was verified. SARS-CoV-2-IgG potency was detected in 25 convalescent plasma which were collected 20-40 days after confirmed Omicron infection, two groups of mixed plasma samples WP1 and WP2 were prepared according to the SARS-CoV-2-IgG results, and pseudovirus neutralization experiments with different virus strain (prototype strain, BA. 1,BA.2, BA.4/5, BF.7, BQ.1.1) were carried out to determine the distribution of neutralizing antibodies against different virus strain. SARS-CoV-2-IgG potency of representative mixed plasma collected from 14 plasma stations subordinate to the company before and after Omicron strain infection was detected, including Omicron convalescent plasma (OP) collected from different plasma stations from December 2022 to May 2023 and normal pool plasma (VN) feed in March 2023 which collected from March 2022 to December 2022. According to the results, the difference and the change rule with time of SARS-CoV-2-IgG before and after Omicron strain infection were analyzed. 【Results】 The linearity of SARS-CoV-2-IgG ranged from 6.25 to 200 EIU/mL, the accuracy in-batch ranged from 81.793% to 106.985%, the precision in-batch ranged from 1. 100% to 13.000%, and the total error in-batch ranged from 2.988% to 22.679%. The accuracy between batches ranged from 90.788%to 96.893%, the precision between batches ranged from 4.870% to 6.272%, and the total error between batches ranged from 9.192% to 15.399%. The results of pseudovirus neutralizing antibody showed that the potency of different virus strain neutralizing antibodies were in the order of prototype strain>BA.2>BA.4/5>BF.7≈ BQ.1.1>BA.1 and the correlation between WP1 and WP2 was high (Pearson r=0. 931 1, P=0.002 3) which indicated that the potency distribution of neutralizing antibodies of different virus strain in Omicron convalescent plasma was basically stable. Compared with the mixed convalescent plasma sample G128 collected in June 2022, the potency of Omicron neutralizing antibodies of WP series were significantly higher, the ratio of BA.2 antibody to prototype antibody increased from 26.9% (before infection) to 82.6%-87.5% (after infection). The results of VN series before Omicron infection were < 100 EIU/mL, and the results of OP series after Omicron infection showed that the plasma collected from the beginning of December 2022 was the peak of antibody in the same month,and then dropped sharply, entering a short plateau in February-March 2023 (potency was about 40% of the peak value),and then dropped sharply again in April (potency was about 20% of the peak value). 【Conclusion】 The potency and proportion of neutralizing antibody against Omicron subtype in convalescent plasma after COVID-19 Omicron strain infection increased significantly. IgG antibody of plasma donors in different regions reached its peak in the month of infection, then continued to dropped sharply. The best collection period of plasma that can be used for human COVID-19 immunoglobulin for intravenous injection was 1 to 2 months after infection.

3.
Preprint em Inglês | bioRxiv | ID: ppbiorxiv-437224

RESUMO

To investigate the duration of humoral immune response in convalescent coronavirus disease 2019 (COVID-19) patients, we conduct a 12-month longitudinal study through collecting a total of 1,782 plasma samples from 869 convalescent plasma donors in Wuhan, China and test specific antibody responses. The results show that positive rate of IgG antibody against receptor-binding domain of spike protein (RBD-IgG) to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the COVID-19 convalescent plasma donors exceeded 70% for 12 months post diagnosis. The level of RBD-IgG decreases with time, with the titer stabilizing at 64.3% of the initial level by the 9th month. Moreover, male plasma donors produce more RBD-IgG than female, and age of the patients positively correlates with the RBD-IgG titer. A strong positive correlation between RBD-IgG and neutralizing antibody titers is also identified. These results facilitate our understanding of SARS-CoV-2-induced immune memory to promote vaccine and therapy development.

4.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-20036145

RESUMO

Currently, there are no approved specific antiviral agents for 2019 novel coronavirus disease (COVID-19). In this study, ten severe patients confirmed by real-time viral RNA test were enrolled prospectively. One dose of 200 mL convalescent plasma (CP) derived from recently recovered donors with the neutralizing antibody titers above 1:640 was transfused to the patients as an addition to maximal supportive care and antiviral agents. The primary endpoint was the safety of CP transfusion. The second endpoints were the improvement of clinical symptoms and laboratory parameters within 3 days after CP transfusion. The median time from onset of illness to CP transfusion was 16.5 days. After CP transfusion, the level of neutralizing antibody increased rapidly up to 1:640 in five cases, while that of the other four cases maintained at a high level (1:640). The clinical symptoms were significantly improved along with increase of oxyhemoglobin saturation within 3 days. Several parameters tended to improve as compared to pre-transfusion, including increased lymphocyte counts (0.65x109/L vs. 0.76x109/L) and decreased C-reactive protein (55.98 mg/L vs. 18.13 mg/L). Radiological examinations showed varying degrees of absorption of lung lesionswithin 7 days. The viral load was undetectable after transfusion in seven patients who had previous viremia. No severe adverse effects were observed. This study showed CP therapy was welltolerated and could potentially improve the clinical outcomes through neutralizing viremia in severe COVID-19 cases. The optimal dose and time point, as well as the clinical benefit of CP therapy, needs further investigation in larger well-controlled trials. Significance StatementCOVID-19 is currently a big threat to global health. However, no specific antiviral agents are available for its treatment. In this work, we explored the feasibility of convalescent plasma (CP) transfusion to rescue severe patients. The results from 10 severe adult cases showed that one dose (200 mL) of CP was welltolerated and could significantly increase or maintain the neutralizing antibodies at a high level, leading to disappearance of viremia in 7 days. Meanwhile, clinical symptoms and paraclinical criteria rapidly improved within 3 days. Radiological examination showed varying degrees of absorption of lung lesions within 7 days. These results indicate that CP can serve as a promising rescue option for severe COVID-19 while the randomized trial is warranted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...